The cooling tower is an equipment designed with a focus on the transfer of residual heat from a certain industrial process to the atmosphere, through evaporative thermal dissipation, lowering the temperature of the circulating water. The EMC (MIXED CONCRETE STRUCTURE) 38, 45, 55, 68, 76, 86, 100 and 121 models, with air draft drawn in countercurrent to water, have induced ventilation, i.e, from the inside out, with air intake horizontally and discharge of air vertically in an ascending movement, being indicated for large projects covering any possibilities of thermal loads and water flows, with multiple cell arrangement, counting on PRFV (Fiberglass reinforced polyester) closure and a cooled water basin in concrete, with pillars and beams up to the height of the diffuser also in concrete. Contact ALFATERM's experienced technical team and schedule a visit with one of our engineers!
Model | EMC 38 | ||
---|---|---|---|
A | 3560 | ||
B | 5600 | ||
C | 6760 | ||
D | 6550 | ||
E | 6550 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 4680 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 6000 | |
Oper. | 9120 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 45 | ||
---|---|---|---|
A | 3900 | ||
B | 6600 | ||
C | 6600 | ||
D | 6745 | ||
E | 6745 | ||
F | N | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 4745 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 6800 | |
Oper. | 10350 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 55 | ||
---|---|---|---|
A | 4400 | ||
B | 7500 | ||
C | 7500 | ||
D | 7680 | ||
E | 7680 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5290 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 8200 | |
Oper. | 12500 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 68 | ||
---|---|---|---|
A | 4900 | ||
B | 8350 | ||
C | 8350 | ||
D | 8660 | ||
E | 8660 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2390 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 9800 | |
Oper. | 14900 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 76 | ||
---|---|---|---|
A | 5700 | ||
B | 8640 | ||
C | 8640 | ||
D | 8960 | ||
E | 8960 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | |||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 11500 | |
Oper. | 16600 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 86 | ||
---|---|---|---|
A | 6100 | ||
B | 9300 | ||
C | 9300 | ||
D | 9610 | ||
E | 9610 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 12100 | |
Oper. | 18400 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 100 | ||
---|---|---|---|
A | 6100 | ||
B | 10080 | ||
C | 10080 | ||
D | 10390 | ||
E | 10390 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5225 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 13700 | |
Oper. | 20900 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
13. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|
Model | EMC 121 | ||
---|---|---|---|
A | 7000 | ||
B | 11000 | ||
C | 11000 | ||
D | 11310 | ||
E | 11310 | ||
F | NOTA 7 | ||
G | |||
number of filling layers | |||
2 | 2570 | ||
3 | |||
4 | 2670 | ||
5 | |||
6 | |||
H | |||
number of filling layers | |||
2 | 5425 | ||
3 | |||
4 | |||
5 | |||
6 | |||
with axial fan weight (KG) | Emb. | 15500 | |
Oper. | 23600 |
01. | DIÂMETRO E FURAÇÃO DA CONEXÃO DE ENTRADA DE ÁGUA CONFORME NORMA ANSI B16.5 (#150 LIBRAS) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
02. | DIMENSÕES EM MILÍMETROS (MM) | ||||||||||||||
03. | L.F.A. = LIMITE DE FORNECIMENTO ALFATERM | ||||||||||||||
04. | PREVER SUPORTE DE APOIO PARA TUBULAÇÃO | ||||||||||||||
05. | ALTURA DA BACIA "I" DEVERÁ SER DEFINIDA PELO CLIENTE | ||||||||||||||
06. | OPCIONALMENTE, A TORRE PODE SER FORNECIDA COM ESCADA E PASSADIÇO PARA ACESSO AO DIFUSOR E VENTILADOR | ||||||||||||||
07. | A DIMENSÃO "F", REFERENTE À ALTURA DA ENTRADA DE AR, VARIA DE ACORDO COM AS CONDIÇÕES DE OPERAÇÃO | ||||||||||||||
08. | O CLIENTE DEVERÁ PREVER VÁLVULA PARA CONTROLE DE FLUXO DE ÁGUA QUENTE | ||||||||||||||
09. | 'BG' = ENCHIMENTO TIPO BLOCOS DE GRADES EM FORMATO DE ONDAS CRUZADAS EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
10. | 'BRT' = ENCHIMENTO TIPO BARRAS DE RESPINGO TUBULARES EM POLIPROPILENO, POLIPROPILENO ANTI-CHAMA V-0 OU POLIPROPILENO ANTI-CHAMA V-2 | ||||||||||||||
11. | DISTÂNCIA MÍNIMA E ALTURA MÁXIMA DE 1500 MM PARA PAREDES E OBSTÁCULOS | ||||||||||||||
12. | SUJEITO A MODIFICAÇÕES SEM AVISO-PRÉVIO | ||||||||||||||
specification example |
|